| Specification | Value |
| Sensor Type | MiniPID T2 10.0 eV Sensor |
| Sensitivity | Benzene specific within typical petrochemical matrix |
| Detectable Range | 0.02 ppm – 20 ppm |
| Measuring Frequency | One Minute |
| Lower Level of Detection | 0.02 ppm (20 ppb) (10 ppb resolution) |
| Accuracy | +/- 50 ppb or +/- 10%, whichever is greater* |
| Temperature Stability | Internally heated |
| Flow Rate | Sample flow rate ≥ 100 ml/min |
| Display | Graphic BW LCD 64 x 128 pixels with backlight |
| Bright LEDs for normal operation, fault and alarm |
| Two magnetic switches for menu operation |
| Operating Temperature | Recommended operating range of -20 oC to +50 oC (-4 oF to +122 oF) for optimum performance** |
| Approvals | 4FTZU 14 ATEX 0172X |
| Ex II 2G Ex db IIB+H2 T4 Gb |
| Tamb. = -20 oC to +55 oC |
| IECEx FTZU 14.0030X |
| Ex db IIB+H2 T4 Gb |
| Tamb. = -20 oC to +55 oC |
| QPS LR1621-1 |
| Ex db IIB+H2 T4 Gb |
| AEx db IIB+H2 T4 Gb |
| Ta= -20 oC to +55 oC |
| Ingress Protection Rating | IP65 |
| Humidity | 0 – 99 % RH |
| Minimum Service Period | 6 months – PID lamp, electrode stack, inline filter, VRV restrictor, Hydrophobic & carbon filter replacement |
| 12 months – PID lamp, electrode stack, inline filter, VRV restrictor, hydrophobic & carbon filter, Airsep filter |
| Cable Entry | Two ¾ NPT gland threads |
| Power Requirements | Vin (nom) 24 V DC @ 3.2 A (recommended) |
| Vin (max) 32 V DC @ 2.4 A |
| Vin (min) 19 V DC @ 4.0 A |
| Communication | Isolated 4-20 mA output |
| Isolated RS 485 Modbus connection via ASCII or RTU (simplex/half duplex or fully duplex) |
| Micro USB (PC Software) |
| Data Storage | On board MMC, minimum of six months (2GB) |
| Relay Output | Two isolated outputs, voltage free, 24 v DC @ 1.25 A |
| Weight and Dimensions | 15 kg (33 lbs) |
| 219 x 219 x 172 mm (8.6 x 8.6 x 6.8” approx.) |
| Gas Sample Line | 10 m max length, PTFE, 6 mm OD, 4 mm ID |