Falco 2 Diffused Fixed VOC Gas Detector

The Falco 2 Instrument is available as either a pumped and diffused model and currently has four detection ranges available to choose from, most suited to your application. The Falco 2 fixed VOC Gas Detector, Diffused model, is an intrinsically safe and ATEX certified instrument making it approved for use in ATEX-zoned hazardous areas. Our fixed gas monitor is designed with Typhoon technology, making it able to withstand exceptionally harsh environments, including 0-100% relative humidity and condensing humidity, and temperatures from -40 to +50 °C without any compromise in performance. In addition, the Diffusive model also has an externally located Intrinsically Safe sensor for quick and easy servicing without the need for a hot work permit and only requires annual maintenance. Dual certification allows your fixed VOC gas detector to be serviced and calibrated in a hazardous environment without having to remove power!
Our Products Are…
  • Economically Priced
  • Futuristic Technology
  • Guaranteed Performance with Premium Quality
  • High Reliability
SpecificationValue
SensorPhotoionisation detector
Detection ranges and sensitivity with 10.6 eV lamp fitted*10.0 ppm, 0.001 ppm
50.0 ppm, 0.01 ppm
1000 ppm, 0.1 ppm
3000 ppm, 1 ppm
Detection ranges and sensitivity with 10.0 eV lamp fitted*50.0 ppm, 0.01 ppm
Response Time (T90)Diffused models: <30 seconds**
Accuracy± 5 % or ± 1 digit
User InterfaceOLED high contrast white on black: 128 x 64 pixels
Screen size: 35 mm (w) x 17.5 mm (h)
5 magnetic switches with LED confirmation (up, down, left, right and enter)
Status indicatorBright visible status indicator: RED, AMBER, GREEN
Output4 – 20 mA
2 programmable relays
RS 485 Modbus
Falco diffused environmental specificationOperational Temperature: – 20 to 50 °C 0-100 % RH and condensing humidity
Storage temperature: – 20 to 60°C
Ingress ProtectionMain Unit:IP65
Sensor Head: IP65
PowerWorking voltage: 8 to 40 Vdc
Typical 2 W, Max 7 watts
Mechanical Interface2 x cable entry points with M25 threads (left and right)
Mounting Points2 x M8
Weight and Dimensions2.5 kg
223 (h) x 192 (w) x 115 (d) mm
EMCEMC Directive 2014/30/EU
CertificationII 2G db ib IIC T4 Gb
ISO9001:2015